Leq (equivalent continuous sound level) is the energy-averaged dB over your whole session — the correct metric for noise exposure. This meter computes Leq correctly via energy averaging.

Live Tool — Leq Meter

Leq Meter — Live Leq

Live Leq with true energy averaging. Measure the whole period you care about — Leq weights loud moments correctly.

Ready to measure
---
dB
Uncalibrated estimate
Allow microphone to start

Allow Microphone Access

Click to enable your microphone for real-time sound level measurement.

Visualization

Start measuring to see visualization

Statistics

0:00
Current --- dB
Minimum --- dB
Maximum --- dB
Average --- dB
Peak --- dB
RMS ---
Leq --- dB

Safe Exposure Calculator

NIOSH

85 dB = 8 hours. Every +3 dB halves time. Based on current average.

dB
Max Daily Time
8 hours
Safe for all day
At 85 dB, 8h limit. +3 dB halves.

Use average (not peak) for exposure. For compliance, use certified meter.

Export Data

Download measurements

The meter below shows Leq dB live in Statistics and Advanced panels. Use the full session, not a 3-second snapshot.

What Leq Means

Leq (equivalent continuous sound level) answers: what steady level would carry the same total sound energy as the actual fluctuating sound did over the measured period? It is the energy average:

Leq = 10·log₁₀( (1/N) Σ 10Li/10 )
where each Li is a frame's dB SPL and N is the number of frames. Energy — not decibels — is averaged, then converted back to dB.

This is the metric professionals use for exposure and reporting because it correctly weights loud moments. See the full derivation and the Noise Exposure guide for why Leq is the right input to exposure thinking.

Why Leq Is Different from a Simple Average

Averaging decibels arithmetically is wrong: dB is logarithmic, so a brief loud burst carries far more energy than the arithmetic suggests.

Numeric example:

Three one-second frames: 80 dB, 80 dB, 100 dB.

  • Arithmetic mean: (80 + 80 + 100)/3 = 86.7 dB — understates energy.
  • Energy average (Leq): 10·log10( (1080/10+1080/10+10100/10)/3 ) = 95.4 dB — correct.

The 100 dB second dominates total energy. Leq reflects that; a plain mean hides it. Our meter corrected to true energy averaging (see Changelog).

Interactive: Leq vs Average

Arithmetic mean
—
Leq (energy)
—

Demonstrates why exposure assessments must use Leq. Try "85, 85, 85" (steady → Leq = mean) vs. "70, 70, 100" (variable → Leq >> mean).

How to Measure Leq Here

  1. Open the meter; select A-weighting and Fast (or Slow) as desired — Leq integrates raw frames regardless of display smoothing.
  2. Measure the entire period of interest (e.g. whole commute, full lesson, full task). Leq needs duration to be meaningful.
  3. Read Leq in Statistics / Advanced Controls. Export CSV/JSON to preserve it, or save to Journal.
  4. Compare Leq across days/rooms to quantify change; feed Leq + duration into the Exposure Calculator.
Time vs. frequency weighting: Leq here is frequency-weighted (A/C/Z as selected) and integrated over wall-clock time. Time weighting (Fast/Slow/Impulse) smooths the live display but does not alter the energy integral.

FAQ — Leq Meter

What does Leq mean?
Equivalent continuous sound level — the steady dB that would carry the same total energy as the actual varying sound over the measured duration.
How is Leq calculated?
By averaging linear energy: Leq = 10·log10(mean(10^(Li/10))). Loud frames dominate the result, which is physically correct.
Is Leq the same as average dB?
Only when the level is perfectly steady. For fluctuating sound Leq is higher than the arithmetic mean — sometimes dramatically — because energy matters, not raw dB numbers.